CASE STUDIES

Energy performance is never one-size-fits-all. A unit’s position in a building, a block’s orientation, a client’s budget or a lender’s green-loan threshold all change what “good” looks like — and what it takes to get there. These projects, from single dwellings to a 136-apartment development, show how we model early, test the options, and find the most cost-effective path to the result.

Results at a glance

ProjectLocationTypeResult
Multi-unit apartment developmentCanberra, ACT136 apartments, 2 buildings (Class 2)Up to 8.9 stars
New home for a green loanWestern AustraliaSingle dwelling8 stars (loan secured)
Exposed corner-block homeClimate Zone 6Single dwelling6.4 → 7 stars
Single-storey homeBallarat, VICSingle dwelling4.2 → 7 stars
Three-storey duplexCharnwood, ACTDuplex5 → 7 stars

136 apartments in Canberra — performance tuned unit by unit

Canberra, ACT · 136 apartments across 2 Class 2 buildings · up to 8.9 stars

The challenge

A large residential development in Canberra — 136 apartments across two Class 2 buildings — where thermal performance varied dramatically from unit to unit. Depending on position, orientation and elevation, ratings ranged from 6 stars at the low end to 8.9 stars at the best. The task was to bring every unit to target while understanding exactly what drove the differences.

Our approach

We modelled the development in detail, with windows at a U-value of 3.5 and thermal bridging minimised through strategic insulation — 50mm rigid insulation below ground-floor slabs and 100mm ceiling insulation to the top floors. Modelling early let us see the patterns clearly:

  • Units with neighbours above and below consistently rated higher, thanks to reduced heat loss through shared walls and floors.
  • North and north-east orientations made a significant difference to performance.
  • First- to third-floor units, especially with mid-level adjacency, performed best.

We then gave particular attention to the harder cases: top-floor units, more exposed to wind chill and open air, carried higher heating loads; south-facing units had reduced solar access; and basement-adjacent units needed carefully considered floor-slab insulation to hit their targets.

The result

A development where every unit meets its performance target and the best reach 8.9 stars — a clear example of how nuanced multi-residential performance is, and how much can be optimised when the modelling is done early and smart.

An 8-star home — and a green loan — in Western Australia

Western Australia · Single dwelling · 8 stars, loan secured

The challenge

A Western Australian homeowner wanted to build a new home and qualify for a green loan, which required at least 7.5 NatHERS stars. Neither his designer nor his builder had reached that level before.

Our approach

We modelled close to 50 scenarios across construction, window and shading options, then narrowed them to the 23 that matched his vision. Scenario 21 reached the 7.5-star threshold while staying close to his preferred construction — double brick with 50mm insulation to the ground floor, reverse brick veneer with R2.5 upstairs, R4.1 + R1.3 ceiling insulation, uPVC windows with mixed single and double glazing, ceiling fans and external louvres for cooling, a highlight louvre to the north, and an insulated panel-lift garage door.

We didn’t stop at compliance. Scenario 20 pushed the home to a full 8 stars — insulated double brick on both floors with EIFS cladding upstairs, a waffle-pod slab and suspended concrete upper floor, double glazing throughout with minimal aluminium, fewer skylights to reduce heat gain, and refined window heights and flooring materials, all while keeping the same passive-cooling strategy.

The result

A compliant, high-performing 8-star home — and the green loan the client was aiming for.

Solving overheating on an exposed corner block

Climate Zone 6 · Single dwelling · 6.4 → 7 stars

The challenge

A corner block in Climate Zone 6 with north- and east-facing road frontages. The exposure brought wonderful natural light, but with no shading from neighbouring structures it also meant high solar gain and a real risk of overheating — and the owners had chosen not to install ceiling fans, a common summer-heat solution.

Our approach

We recommended double glazing to most of the north- and east-facing windows. The insulating air gap between the panes cut solar heat gain and brought the overheating under control. As a bonus, those same road-facing windows gained a noticeable acoustic improvement, reducing external noise and making the home feel calmer and more private.

The result

From a 6.4-star baseline to a compliant, comfortable 7 stars — one smart solution solving two problems at once.

From 4.2 to 7 stars in Ballarat

Ballarat, VIC · Single-storey home · 4.2 → 7 stars

The challenge

A single-storey home in Ballarat, Victoria, starting from a 4.2-star rating — a long way from the 7-star benchmark.

Our approach

We identified two effective routes. The simplest was high-performance Net Zero Plus windows with U-values of 1.0 or lower, which reached compliance almost effortlessly. Alternatively, a combination of increased ceiling insulation, adjusted window sizes and double glazing with U-values up to 2.11 achieved the same target.

The result

A comfortable 7-star home, reached without unnecessary complexity — and with options that let the client choose the path that best suited their design and budget.

A three-storey duplex to 7 stars in Charnwood, ACT

Charnwood, ACT · Three-storey duplex · 5 → 7 stars

The challenge

A three-storey duplex in Charnwood, ACT, with an initial rating of 5 stars.

Our approach

Again we mapped two pathways. Net Zero Plus windows with U-values of 1.5 or lower met the 7-star target comfortably. Alternatively, enhancing the floor and ceiling insulation and upgrading to double-glazed windows with U-values up to 3.11 also reached the goal.

The result

A compliant 7-star duplex, achieved with strategic upgrades and without compromising the design intent.

CURIOUS HOW YOUR NEXT
PROJECT COULD PERFORM?

Whether it’s a single home or a multi-residential development, we’ll model it early and find the smartest, most cost-effective path to your target. Send us your plans for a tailored quote, or book a free energy efficiency audit.